CERTCOM reports the following diagnostic numbers for command input, session, and batch errors. Text can include the actual command, parameter, file or state that failed. For certificate-management errors (201xx), use the CERTCOM Command Diagnostics.
Errors
An error rejects the current input or operation. Inspect the message and correct the stated condition before retrying. A batch can stop when its error limit is exceeded; do not assume later commands ran. The table describes the condition and recovery, rather than reproducing variable message text.
|
Number |
Condition/cause |
Recovery |
|---|---|---|
|
10101 |
Invalid command or command/object combination. |
Use HELP to select a registered command and object. |
|
10102 |
Command selection is not unique. |
Enter the complete command name. |
|
10105 |
Required command object is missing. |
Supply the object listed by HELP for the command. |
|
10107 |
Extra input follows the permitted syntax. |
Remove extra operands or clauses. |
|
10108 |
Unknown parameter. |
Check HELP and use a supported parameter name. |
|
10109 |
Ambiguous parameter or operand selection. |
Use its complete name. |
|
10110 |
Required parameter is missing. |
Supply the required parameter and value. |
|
10116 |
Destructive file operation needs explicit replacement confirmation. |
Verify the filename before supplying the documented exclamation-mark confirmation. |
|
10117 |
Value does not match the expected data type or required file condition. |
Correct the value or file identified by the message. |
|
10118 |
Command is allowed only interactively. |
Run it in an interactive session. |
|
10119 |
Protected password value is unavailable. |
Supply it through the approved protected input procedure. |
|
10120 |
Negation is not valid for this parameter. |
Use a supported clause without the invalid negation. |
|
10121 |
Parameter is specified more than once. |
Keep a single occurrence. |
|
10122 |
Command abbreviation is invalid in this input context. |
Use the complete command name in batch/command files. |
|
10123 |
Object abbreviation is invalid in this input context. |
Use the complete object name. |
|
10124 |
Parameter abbreviation is invalid in this input context. |
Use the complete parameter name. |
|
10125 |
Invalid ALLOW command operands. |
Use HELP ALLOW and specify a supported warning/error limit. |
|
10128 |
Invalid input or selection. |
Correct the input or selection described by the message. |
|
10129 |
An object selector was supplied where it is not permitted. |
Use the command's documented target syntax. |
|
10130 |
OBEY input file cannot be opened. |
Check its name, existence and access permissions. |
|
10131 |
Command requires an available session. |
OPEN the intended monitor, then check STATUS SESSION. |
|
10132 |
Handler is not implemented. |
Check installed-version support and contact support if needed. |
|
10133 |
Command plugin could not initialize. |
Inspect the diagnostic and service state; correct the cause before retrying. |
|
10134 |
Command plugin cleanup failed. |
Inspect state and diagnostic output before submitting further work. |
|
10135 |
Parameter combination violates a command rule. |
Correct the combination described by the diagnostic. |
Warnings
|
Number |
Condition/cause |
Effect and recovery |
|---|---|---|
|
10201 |
Warning limit exceeded. |
Input-file execution stops; inspect earlier warnings and correct them or explicitly choose an appropriate ALLOW limit. |
|
10202 |
Error limit exceeded. |
Input-file/batch execution stops; correct the earlier error and establish which commands ran before resubmitting. |
Certificate-management commands can also return the ActivCERT-specific command diagnostics.